| BIO-HYDRAULIC FLUIDS
|
For the performance
you need, with the protection you need.
Available in True Viscoscities: ISO 22, 32, 46, 68, 100,
as specified by manufacturers.
For Off-Highway Construction and use in other Environmentally
Sensitive Areas |
|
|
| United States
Army 1-Year Hydraulic Fluid Test Results |
| Property
|
Initial
Synthetic |
Vegetable
|
Final Synthetic
|
Vegetable
|
| Viscosity,
cSt |
30.25 |
31.8 |
26.01 |
32.23 |
| Acid Number,
mg KOH/g |
.90 |
.62 |
.60 |
.66 |
| Pour Point
(°C) |
-56 |
-35 |
-57 |
-38 |
|
| Overall Performance - Satisfactory
after one of the hottest summers on record at Fort Bliss, Texas.
|
|
| Test Results
for ILI biodegradable Bio Hydraulic Fluid |
|
Property |
ASTM Test # |
Criteria |
ILI BIO-Hydraulic |
| Rust Prevention
|
D 665 |
Pass |
Pass |
| Copper
Corrosion |
D 130 |
2 Max |
1A |
| Foaming-Seq
I |
D 892 |
0 @ 10
minutes |
0 |
| Foaming-
Seq II |
D 892 |
0 @ 10
minutes |
0 |
| Foaming-
Seq III |
D 892 |
0 @ 10
minutes |
0 |
| Pour Point
|
D 97 |
|
-30°C
|
| Acid Number
|
D 664 |
|
<1 |
|
Viscosity @ 40°C |
D 445 |
Varies
with Grade |
22-460
|
Hydrolytic
Stability
Copper Panel |
|
(Cincinatti
Milacron Standard) |
|
| % Viscosity
|
|
5 Max |
1B |
| Change
|
|
+5% Max
|
-4.4 |
| % Acid
# Change |
|
±50
|
+16.28
|
| % Insolubles
|
|
25 mg/100
ml Max |
7.5 |
|
| |
| Performance
|
|
Test |
ASTM Test # |
Criteria |
ILI BIO-Hydraulic |
| 4-Ball
Wear |
D 2266
|
0.5 mm
|
0.44 mm
|
| Vickers
35VQ25 Vane Pump Test |
Wt Loss,
mg |
150 mg
(in 3 cartridges) |
41 mg (in
5 cartridges) |
| Dennison
P46 Piston Pump Test |
HF-O Procedure
|
Pass |
Pass |
|
|
Proven biodegradability
|
| Read